Delta
Photogrammetric Equipment

DeltaScan 5 is a professional model that is fully automatic film-roll system.

DeltaScan 4 is a manual roll. Both models are intended for roll-films up to 250 mm wide and 168 mm in diameter. It can scan cut images up to 300x300 mm in size.

DeltaScan 470 is a special large size model intended for 300x450 mm satellite images and satellite 300 mm wide films.

Pre-scan image with improper color balance and weak contrast

Scanner output after automatic settings have been applied
|
Delta Scanner | PlanScan | 3-DAS-1 Digital Camera |
|
DELTA SCANNER - COLOR PHOTOGRAMMETRIC SCANNER
There are 3 different scanner models on the same mechanical basis. All scanners have the same resolution, geometric and radiometric parameters. All the models can scan cut images.
Geometric parameters
-
The scanner provides a high resolution, which is 8 µm (3175dpi)
-
Root mean square error of scanning does not exceed ±2 µm. The value of root mean square error is determined by scanning and measuring the control grid
-
Scanner is supplied with a unit for scanning roll films up to 250 mm wide (300 mm for 300x450 model)
Radiometric parameters
-
Scanner is equipped with a SONY color linear CCD-sensor and a light source based on a power LED array: components that provide superb quality of output images
-
Controller of the CCD-sensor provides an internal 12-bit storage for intensities within each color channel that is transformed by hardware into 8-bit output
-
Scanner provides scanning of both color and black-and-white materials and the scanning software stores output as True Color (24 bit) or gray scale (8 bit) image files
-
The scanning software automatically detects optimal values of exposition, contrast and gamma for each color channel
-
Scanner can perform scanning in two modes: density linear and intensity linear, which provide optimal results for photographs of any quality
-
Scanning time for a 230x230 image in True Color mode at a 16 µm pixel size is 15 minutes
-
Scanning time for a 230x230 image in grayscale mode at a 16 µm pixel size is 6 minutes
Scanning software
-
Works in single image or batch mode (for automatic model)
-
Supports scanning to TIFF (uncompressed or JPEG) and BMP formats where the pixel size is a multiple of CCD pixel: 8, 12, 16, 24, 32, 128 µm
-
Contains a powerful unit for correction and transformation of output images and automatic inner orientation
Technical specification
|
CCD Pixel size |
8µm |
|
Geometric resolution |
1µm |
|
Geometric accuracy (RMS) |
±2µm |
|
Maximal optical density |
3.4D |
|
Optical density range |
2.7D |
|
Radiometric resolution |
12/8 bits per channel |
|
Maximal scanning area |
320x320 mm or 320x450 mm |
|
Maximal roll diameter |
168 mm |
|
Roll film scanning |
Up to 250 or 300 mm wide |
|
CCD-sensor |
Color SONY 3x5300x8 |
|
Light source |
Power LED array |
|
Scanning of non-transparent material |
Optional |
|
Output formats |
Tiled TIFF, Tiled TIFF(JPEG), BMP
Color 24bit, b/w 8bit |
Typical scanning time for standard 230x230 mm photo
|
Pixel size,
µm |
Black-and-white 8bit |
Color 24bit |
|
Time
min |
Size
Mb |
Time
min |
Size
Mb |
|
8 |
12 |
788 |
30 |
2368 |
|
16 |
6 |
197 |
15 |
592 |
|
32 |
4 |
49 |
9 |
148 |
Automatic detection of optimal parameters for scanning:
-
Quick prescan feature allows to build an image histogram, and then software automatically suggests optimal settings for further scanning: exposition, contrast and gamma for each color channel based on the histogram.
-
In automatic film mode you can build summary histogram for whole film or any part of it.
-
Users can set scanning parameters manually by simply clicking on the intensity histogram or on histogram of any color channel.
-
The program immediately reflects the changes on the image.
-
The program can build histograms for areas designated by user and perform image correction for these areas separately.
Scanning software capabilities:
-
Automatic detection of optimal scanning settings
-
Manual setting of scanning parameters and transformation tables for each channel separately
-
Scanning into Tiled TIFF, BMP and DIP formats where the pixel size is a multiple of minimal size: 8,12,16,24,32 …128 µm
-
Density linear mode provides maximum detail and uniform distribution of pixel intensities around the image
-
Scanning positives and negatives in straight and mirror modes
-
The program can apply digital filters during scanning to reduce the noise of the image
-
Geometric calibration and accuracy control by measuring the control grid
-
Radiometric calibration and elimination of irregularity of the light source
-
Generation of output images using only one or two color channels; saving color channels in separate files
-
An option that allows automatic creation of zoom pyramid during scanning
-
Logging every scanning process allows users to view settings for previous processes and restore them, if necessary
Batch-processing mode:
-
Supports multiply jobs/setups per film
-
Uses automatic frame-edge search
-
Calculates summary film histogram in full film prescan mode to provide uniform film images
-
Uses customized film layouts for films with arbitrary numerated frames
Post-processing software
-
Image analysis and histograms
-
Image correction and applying various filters to groups of raster files
-
Resampling images into any other pixel size
-
Merging/splitting color channels from/into separate files
-
Splitting files into fragments or merging fragments into a single file
-
Fast processing of raster files up to 4GB |